Best Answer

Yes, as long as you don't exceed the amperage of the breaker. Say your double pole is 30 amps. You want to run a clothes dryer that uses 10 amps, and a welder that uses 20. They both run off of 220v. You can dry your clothes when you are not welding. You can weld when you are not drying clothes. If you try to do both at once, you may or may not trip the breaker. Technically, you can run as many 220v plugs as you want, as long as you don't exceed the breaker's rating. Say you had a 5 amp air compressor, a 5 amp water pump, and a 10 amp clothes dryer. You can run all three at the same time. Just remember, as you increase voltage, you decrease amperage.

User Avatar

Wiki User

16y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

14y ago

Yes, but there is a code rule that states that if either breaker trips under overload or short circuit conditions both breakers must disconnect the load. Each breaker manufacturer knows of this rule and makes a clip that is pushed on over the handles of both single pole breakers. This clip serves the code rule by making the breakers act as a two pole breaker. If the breakers are being used as a disconnect to isolate the load both "hot" legs will be opened.

This answer is:
User Avatar

User Avatar

Wiki User

13y ago

Yes, otherwise your double pole breaker will shut the other circuit off when one of them trips.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Are two pole circuit breakers 240 volts?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

Can double pole circuit breakers be changed into single to create more room in the pannel box?

Yes. The double pole breaker can be removed and replaced with two single pole breakers. The double pole breakers are only used for 240 volt supply loads.


Can a 220 VAC breaker be single pole or does it have to always be a double pole breaker?

U.S. 240 VAC breakers are always double pole since they are protecting two legs of the circuit.


What is 4 pole circuit breaker?

I have never seen a four pole circuit breaker. Breakers are single, two and three pole. Single pole for 120 volts, two pole for 240 volts and three pole for three phase loads. In North America all neutrals are SN (solid neutrals) and are not switched. In certain applications using a three phase Y-connected load, where complete isolation of the load from the supply is required, the neutral line connects to one pole of a 4 pole circuit breaker.


What is a 2 pole 30A circuit breaker?

Answer for USA, Canada and countries running a 60 Hertz supply service.On a split phase system where you need 240 volts a two pole breaker is used. L1 to N will give you 120 volts for one circuit. L2 to N will give you 120 volts for one circuit. L1 to L2 will give you 240 volts for one circuit.


Why does my heating and air conditioner in my house have 3 double pole breakers - a 30 40 and 50?

In North America a two pole breaker usually represents a load that requires a 240 volt source. Larger current load appliances use 240 volts to reduce the feeder size and there by reduces the cost factor when wiring a building. Two pole 15 amp breakers are used for kitchen counter split receptacles.Two pole 20 amp breakers can be used for baseboard heating and hot water tanks.Two pole 30 amp breakers can be used for clothes dryers and some heating units.Two pole 40 amp breakers can be used for electric ranges.Two pole 50 amp breakers are not common in home wiring circuits. It might be used for an electric furnace or some other high current device.

Related questions

Can double pole circuit breakers be changed into single to create more room in the pannel box?

Yes. The double pole breaker can be removed and replaced with two single pole breakers. The double pole breakers are only used for 240 volt supply loads.


How many Breakers needed to wire an electric furnace?

The electric furnace operates on 240 volts so a two pole breaker is needed.


Can a 220 VAC breaker be single pole or does it have to always be a double pole breaker?

U.S. 240 VAC breakers are always double pole since they are protecting two legs of the circuit.


What does it mean when you have two 30 amp breakers linked together?

Two single-pole 30 amp breakers tied together make a two-pole 30 amp breaker. From this you can power a device that requires 220-240 volts, typically.


What is 4 pole circuit breaker?

I have never seen a four pole circuit breaker. Breakers are single, two and three pole. Single pole for 120 volts, two pole for 240 volts and three pole for three phase loads. In North America all neutrals are SN (solid neutrals) and are not switched. In certain applications using a three phase Y-connected load, where complete isolation of the load from the supply is required, the neutral line connects to one pole of a 4 pole circuit breaker.


What is a 2 pole 30A circuit breaker?

Answer for USA, Canada and countries running a 60 Hertz supply service.On a split phase system where you need 240 volts a two pole breaker is used. L1 to N will give you 120 volts for one circuit. L2 to N will give you 120 volts for one circuit. L1 to L2 will give you 240 volts for one circuit.


How volts comes from a 20amps breaker?

On most residential circuit breaker boxes in North America, each individual breaker represents one 120-volt circuit. Two breakers ganged together represent a 240-volt circuit.


Can a 240 volt receptacle go on a 15 amp circut breaker?

In North America you would need two 15 amp breakers to obtain 240 volts. The wire for a 15 amp circuit would be #14 AWG. So to answer the question, yes a 240 volt receptacle can go on a 15 amp circuit.


Why does my heating and air conditioner in my house have 3 double pole breakers - a 30 40 and 50?

In North America a two pole breaker usually represents a load that requires a 240 volt source. Larger current load appliances use 240 volts to reduce the feeder size and there by reduces the cost factor when wiring a building. Two pole 15 amp breakers are used for kitchen counter split receptacles.Two pole 20 amp breakers can be used for baseboard heating and hot water tanks.Two pole 30 amp breakers can be used for clothes dryers and some heating units.Two pole 40 amp breakers can be used for electric ranges.Two pole 50 amp breakers are not common in home wiring circuits. It might be used for an electric furnace or some other high current device.


In a 220 volt AC single phase circuit the voltage from either leg to the neutral is?

The proper terminology is L1,L2,N. N is for neutral and it is this wire that is grounded. The voltage measurement from the L1 to N will give you 120 volts. Also from L2 to N will give you 120 volts and as you know from L1 to L2 will give you 240 volts. Single pole breakers in the panel board starting at the top, alternate between L1 and L2 all the way down to the bottom. These breakers all have 120 volt outputs. If you plug a 2 pole breaker into two slots then you get 240 outputs because L1 and L2 are adjacent to one another.


What is the difference between a 2 pole and single pole breaker?

Answer for USA, Canada and countries running a 60 Hertz supply service.A single pole breaker is used to supply 120 volts to a 120 volt load circuit and to protect the conductors of that circuit. This is one "hot" wire to the load and then back to the neutral. A two pole or double pole breaker is used to supply 240 volts to a 240 volt load and to protect the conductors of that circuit. This is two "hot" wires to the load without a neutral, eg. baseboard heaters, hot water tanks. The two pole breaker is also used with a neutral when the 240 volt device needs a 120 volt supply for its controls. eg. electric range, dryer.If you mean a 120 breaker with two switches, those are designed to fit an extra circuit into a full breaker panel by removing the single, installing the double, and you now have two breakers in the space of one, each for the rated amps at 120 volts on the same "leg" of the 240 supply. These are not often recommended and some local codes do not permit them to be used more than temporarily.


Why does your air conditioner have two breakers?

Answer for USA, Canada and countries running a 60 Hertz supply service.The use of two breakers supplies a voltage of 240 volts. These two breakers should be common ties together with a single handle. Your air conditioner must operate on 240 volts. To verify this check the nameplate on the unit for the voltage.