Q: How close to a breaker panel can a drain pipe and water lines be?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What type panel does a 4 pole breaker require?

The panel and breaker have to be of the same manufacturer. This way the breaker will fit into the panel. If the panel has a push in bus bar, the breaker must also be the type to accept the bus bar. If the bus bars in the panel are of the bolt in type then the breaker also has to be a bolt in breaker.


You have an elecwaterheater it blows the20amp in line breaker and the 50 amp main?

For a main breaker to trip under these circumstances the rest of the panel is becoming close to its load rating. When the 20 amps breaker trips the rest of the panel is close to or over 30 amps, the 20 amp breaker takes it over the top. What trips a HWT breaker is usually a faulty heating element. It could be the top one or the bottom one.


What is installing a circuit breaker?

It is inserting a breaker into a service panel.


What is function of damping relay in circuit breaker?

The anti-pumping relay is a device in circuit-breaker whose function is to prevent multiple breaker closures. For instance, if the operator gives the closing command to the breaker by pressing the close button and the breaker closes. However, a fault in the system causes the breaker to trip. Since the close command is still in the pressed condition, there is a chance of the breaker closing again and being tripped by the relay multiple times. This can damage the closing mechanism of the breaker. The anti-pumping relay prevents this by ensuring that the breaker closes only once for one close command from the control panel.


Can a Siemens breaker push on be a replacement breaker for a Westinghouse breaker?

only if listed in the panel board


Will cutler hammer breaker panel fit a GE breaker?

No, a Cutler Hammer will not work in a GE panel or vice versa.


You lost a voltage leg by connecting the ground wire to the circuit breaker but com ed wires are still energized?

Yes this could be true. The breaker to the load will have tripped. The main breaker should still be allowing voltage to the distribution panel because it did not trip. If the main breaker tripped then the distribution panel must have been close to maximum amperage and the shorting of the branch circuit was enough to trip the mains.


When a voltage leg is lost by connecting the ground wire to the circuit breaker are com ed wires still energized?

Yes this could be true. The breaker to the load will have tripped. The main breaker should still be allowing voltage to the distribution panel because it did not trip. If the main breaker tripped then the distribution panel must have been close to maximum amperage and the shorting of the branch circuit was enough to trip the mains.


What can cause house electricity to cut on and off?

Loose supply lines on the supply line from the pwr pole connections. Bad main breaker in fuse panel Rare! but loose screw on wire feed in main breaker connection.


What size breaker do you use for a 100 amp sub panel?

A 100-A sub-panel would be fed from a 100-A breaker.


If an electrician have a circuit that pulls a load of 10 amps what size breaker must that circuit be protected by?

If you are talking about a breaker in a house panel then a 15 amp breaker would be used. It is the smallest amperage breaker that you will find in a house panel.


Will a siemens breaker work in a GE panel?

Possibly. Depends on which model Siemens breaker you have.