Best Answer

=== === Any socket outlets or wiring to pumps, etc must be protected by a GFCI, not only by the main circuit breaker on the house AC power supply panel.

Sounds like there is water somewhere in the circuit and that is causing the GFCI to keep tripping every time you press the RESET button. The GFCI is doing its job to protect you and your family from electrocution.

Turn off all power at the main panel and then check all wiring, junction boxes, outlets, etc. in the circuit for water. Every part of the circuit must be allowed to dry thoroughly before the GFCI will allow you to reset it. Then be sure to protect any connections in the circuit from getting any water spray or splashes in future.

Really this work should be done by a licensed electrician who will know exactly where to check and what to do to make your electric pool pump - and any socket outlets in the same circuit - safe to use in future.

Is the distance from the panel to the pool very far or long, A ground fault breaker is looking for a difference in potential the longer the distance the more sensitive they become. What you may have to do is put a ground fault outlet by the pump and put the wiring in a regular breaker. IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS.

If you do this work yourself, always turn off the powerat the breaker box/fuse panel BEFORE you attempt to do any work AND always use a meter or voltage indicator to insure the circuit is, in fact, de-energized.

User Avatar

Wiki User

15y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How do you install an electric pool pump I've already hooked up the wiring and it's been working fine for three month's. Then the breaker tripped now it keeps tripping when I try to turn pump back on?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Which wire is used to install a double oven and a stove?

Normally older ovens required a AWG #8 wire on a 40 amp breaker. On a modern double oven I would recommend you install AWG #6 on a 50 amp breaker. That way you are safe and will not have to worry about the breaker tripping. It will cost a little more but is worth it in the long run.


How do you install shunt trip breaker?

A shunt trip breaker is installed like any other molded case breaker. The only difference is that it has an internal tripping coil that is usually connected to a C.T. The breaker is usually mounted in a MCC cabinet The top of the breaker is bolted to the MCC bus bars and the bottom of the breaker is connected to the load. The load conductors pass through the C.T.'s.


How do you replace a 15 amp breaker in the circuit box?

The breaker will have a black wire connected to it. Turn off the main breaker and then disconnect that black wire from the breaker. The breaker will snap into the main bar. Remove the breaker and install the new one. Reconnect the black wire to the breaker and then install the cover and turn the main breaker back on.


Does DTE Energy install breaker boxes?

To the best of my knowledge, DTE dose not install breaker boxes. To have one installed you should contact an electrician.


If you install a 30A 240V GFI breaker will this be ok or will the cycles the dryer has prematurely fail the breaker?

I suspect you mean GFIC breaker. The dryer will not cause the breaker to fail.


How to install an Electric brake?

To install electric brakes, first remove the wheel. Then remove the dust cap, nut, and washer; this will be the place where you install the electric brakes.


How to bypass single phase circuit breaker?

You should never try to bypass any protection devices. This is just asking for trouble down the road. The circuit breaker is there to protect the wiring to the device that is powered from that breaker. If the load is too large and keeps tripping the breaker install a larger breaker with new wiring sized to the breaker to accommodate the higher load current. Again do not bypass circuit breakers as you will have no short circuit or overload protection.As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliancesalways use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.


What size breaker can you use on a 7500watt generator?

Depends on the wire size you are using. If the generator breaker is a 30 amp then install a 30 amp breaker.


Can you install a sump pump outside?

Yes but it has to be protected against freezing and tripping hazard and a GFI


How do you install a miniature breaker?

A miniature breaker is just two breaker that fit into one breaker slot. These types of breakers are designed to install the same as a full size breaker. Different types of breakers have different mounting configurations to the panels bus bars so installation instructions are not possible without knowing the make and type.


What is a sentence with the words circuit breaker in it?

Example sentence - We hired an electrician to at the circuit breaker and install an updated panel.


How to install an electric fence?

Electric fences can be tricky to install if you do not have the proper directions. Here is a link to how to install an electric fence properly - http://www.afence.com/Electric_Fence/how_to_elecfence/elecinstall.htm