answersLogoWhite

0


Best Answer

unlimited

User Avatar

Wiki User

11y ago
This answer is:
User Avatar
More answers
User Avatar

Anonymous

Lvl 1
3y ago

1

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How many switches can be connected to a contactor coil control circuit?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Movies & Television

How are safety switches wired to the holding coil?

In control circuit wiring the safety switch is in series with the holding coil.


How can you include phase failure relay in your star delta motor starter circuit?

The star delta motor starter circuit has to have a control voltage to energize the motor magnetic contractors. A phase failure relay monitors all three phases of the incoming supply lines. The phase failure relay also has auxiliary contacts on it. There are usually two sets of "C" form contacts. The control voltage for the starter circuit must be connected across the normally open (N.O.) contacts of one of these two sets. When the phase monitor is energized these N.O. contacts close supplying the control voltage to the circuitry of the star delta starters. If there is a phase interruption, phase reversal or phase loss, the phase failure relay will de-energize and the N.O. contacts will go back to their de-energized state. If the star delta motor starter is in use at the time, its control circuitry voltage will be lost and the delta motor magnetic contactor will open. The opening of this contactor will disconnect the motor from the failed three phase supply.


When using a 3 wire control circuit to control a magnetic motor starter the part that will open the control circuit when an overload occurs will be?

The part that opens the circuit is the overload blocks that are situated below the magnetic starter and before the motor load. The latest addition to the electrical code book states that the "hot" wire goes through the overload contacts first before feeding the 3 wire control system. With the supply voltage in this position the whole circuit becomes de-energized when the motor load trips the circuit. The old standard practice on a 3 wire control system, the neutral was connected to the overload relay contacts. When the overload relay tripped it opened the neutral of the coil circuit and the starter dropped out


What is the role of a switch?

A switch is installed in a circuit to stop the current flow. Without the switch there is no way to disconnect the operation of the circuit's load. In modern households the switch is a convenient way to control room lighting from a convenient location. Without switches the circuit power would have to be controlled from the service distribution panel's breakers. In this scenario the breaker would be in the same class as a switch.


What are two uses for variable resistors?

Volume Control Light Dimmer Tone Control Bass Control Treble Control Fan Speed Control

Related questions

How many wires to control a mechanically held contactor?

A contactor is a type of switch. However this switch uses electricity to power an electromagnetic coil to switch on or off power. Hence a contactor needs 2 wires - A live/hot wire and a neutral wire. Generally these are connected across the A1 and A2 terminals of the contactor.


How does magnetic contactor operate?

explain me about the contactor works with examples. if i want to control a motor with contactor. and how i can use contactor in loops with over load and circuit breakers.


What is the purpose of a timer wired into the compressor contactor control circuit on a refrigeration system?

A defrost control typically.


How do switches control circuit?

They break the connection


Can a 3 phase contactor be wired for single phase?

Yes, L1 of the single phase supply is terminated under terminal L1 of the three phase contactor. L2 of the single phase supply is terminated under terminal L2 of the three phase contactor. A conductor from output terminal T2 is then taken to input terminal L3. The single phase load is then connected to the contactor's output terminals T1 and T3. This incorporates all three of the overload blocks on the contactor into the control circuit. With the overloads in the control circuit, if an overload occurs the magnetic contactor's holding coil will drop out and take the load off line.


How do electro pneumatic contactors work?

A contactor is an electrically controlled switch (relay) used for switching a power circuit. an electro pneumatic contactor is similar to the above except it uses a pneumatic signal to initiate the switching of the electric power circuit. an electro magnetic contactor is a contactor driven by an electric control signal. It us usually just called a contactor.


What is meant by main contact and auxiliary contact in magnetic contactor?

The main contact controls the load current to the motor, whereas the auxiliary contact is part of the control circuit -usually connected in parallel with the 'on' pushbutton switch to maintain the control circuit in the energised state, once the on pushbutton has been pressed.


Why is the compressor contactor not sticking in?

A contactor not being energized or closed can be caused by a host of reasons . A shorted or open contactor coil. No control voltage or incorrect voltage present to energize the contactor coil , A safety device opening or breaking the control circuit . A loose or broken control devise or control wire . and possibly more , depending on your a/c units control wiring configuration. Tom H, HVAC proffesional. New Orleans .


What is the function of contactor?

A contactor is used like a switch. It is used to open and close the circuit it is in series with by electrically energizing and de-energizing the holding coil of the contactor. By having this adaptability the circuit can be remotely operated from a distance and the operator does not have to be in close proximity to the circuit. Contactors are used to remotely operate banks of lighting and of course the contactor is used for motor control. On contactors that control motors an additional overload block is added to the bottom side of the contactor to protect the motors if they get into an over load condition. The N.C. contacts in the overload block will open and the holding coil of the contactor will de-energize and drop the motor off line.


When is a lighting contactor required?

A lighting contactor is a special contactor that is used only for control lighting installations. The contact ratings are incandescent rating and not to be used for motor control. The contactor allows banks of lights to be controlled by one device. The controlling devices could be switches, computers or photocells to bring the lights on at any preset times. <<>> A Contactor used to supply the Power to the lights


Can switches control each branch in a parallel circuit separately?

Yes, that's exactly what your light switches are doing at home.


On a heat pump the outside fan is not running when it's in ac mode contactor not pulled in why?

No control power to the contactor coil. You must trace the control circuit back until you find the open switch that is interrupting the flow of power and correct the problem.