It would help to know the voltage of the motor. See related links below for motor connections.
two windings on the stator
A synchronous motor can be a type of 3-Phase AC motor, or not.A synchronous motor is defined by the period of the rotor being synchronized with the frequency of the stator windings' current. The stator windings might be 3-Phase or not (2-Phase would work).Also synchronous motors are not the only type of 3-Phase AC motors. An induction motor could also be 3-Phase AC and has a few advantages and disadvantages over a synchronous motor.
one windingAnswerA three-phase motor has three phase windings, normally (but not necessarily) connected in delta.
The field windings of a three-phase motor are termed 'phase windings'. An 'open phase' means that one of these windings has become open-circuited -i.e. there is a break in the winding. Unfortunately, however, 'line conductors' are often incorrectly referred to as 'phase conductors', so a break in a line conductor could (incorrectly) be called an 'open phase'!
The three windings are made the same to maintain a balance in the motor.
two windings on the stator
is it necessary to have three phase rotor
the motor is good
Is the motor 3 phase? Thats what im guessing. You would get an unbalanced load across the windings of the motor, the other 2 phase's would try to compensate and ruin the windings. 3 phase motors are obviously supposed to have 3 phase input. Weather it be in star or delta. I wouldnt try and run it if i were you!
A synchronous motor can be a type of 3-Phase AC motor, or not.A synchronous motor is defined by the period of the rotor being synchronized with the frequency of the stator windings' current. The stator windings might be 3-Phase or not (2-Phase would work).Also synchronous motors are not the only type of 3-Phase AC motors. An induction motor could also be 3-Phase AC and has a few advantages and disadvantages over a synchronous motor.
what will be the result if the starting winding in a split phase motor fails
one windingAnswerA three-phase motor has three phase windings, normally (but not necessarily) connected in delta.
Motor voltages and amperages can both be tested. The best way to test the continuity of a motor is with a megger. This will check that the motor windings are intact and if there is any voltage leakage to ground or voltage leakage to one of the other two windings in the motor. To check amperages on the motor it will have to be energized. Leave a message in discussion page as to what you are trying to do. <<>> Because there is no such thing as 'phase to phase'! However, there is such a thing as 'line to line', and this can be tested!
The field windings of a three-phase motor are termed 'phase windings'. An 'open phase' means that one of these windings has become open-circuited -i.e. there is a break in the winding. Unfortunately, however, 'line conductors' are often incorrectly referred to as 'phase conductors', so a break in a line conductor could (incorrectly) be called an 'open phase'!
The three windings are made the same to maintain a balance in the motor.
Well the big identifier of a split phase induction motor is the main and aux. winding. The rotor, stator, case, etc. These two windings is what sets it apart from other motors. These windings are phase shifted to produce a rotating magnetic field for starting to allow the motor to have better starting torque.
If the motor was lightly loaded it may continue to run, however in most applications the loss of the phase would cause the motor to stop. Properly wired and it should trip the motor overload device and prevent damage to the motor windings.