== == The washing machine outlet should be ground fault protected on 12-2 wire. The 30 amp dryer circuit should be on 10-3 wire with a ground. <><><> Laundry receptacle outlet for washer, 12/2 with ground yes! GFCI required if receptacle is within 6 feet of sink or duplex receptacle rather than single receptacle [but a GFCI isn't a bad idea anyway...

Dryer, 10/3 with ground and 4-wire outlet and cord set connection at dryer location! NO NEUTRAL BONDING LINK!

1) NEC requires a disconnecting means [plug and receptacle works] if equipment [dryer] is not within sight of the power source [in this case, if the panel is in the garage]

2) You were never allowed to use the ground wire to carry neutral current, so you need an insulated white or grey neutral [this means three wire]

3] You are not longer allowed to use the neutral jumper at the terminal in the dryer for a chassis ground [with certain limited exceptions - existing ungrounded three wire cable and new dryer] Ground wire goes to chassis. <><><>

As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.

Before you do any work yourself,

on electrical circuits, equipment or appliances,

always use a test meter to ensure the circuit is, in fact, de-energized.

IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What are the NEC requirements if a laundry circuit is to be installed in a basement of a dwelling for a washing machine and the dryer will be connected to a 30A dryer receptacle?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Can I install a GFCI receptacle from an existing receptacle in the basement?

Yes, there is no reason why this can not be done. In fact a benefit of this is that every receptacle downstream from this new receptacle will also be protected by the GFCI receptacle.


Is it against electrical codes in Ohio to mount a receptacle box for a washing machine on a wood spacer on a masonry wall in a basement laundry?

Should be fine as long as you use a GFIC receptacle and mount at the proper height. You need to contact your local code enforcement people. Normally each locality has their own requirements to be followed.


What is the little trap door on the flooring of a fireplace and what is it for?

In older constructed fire places, the trap door led to a receptacle under the floor, accessible from the basement, into which you could sweep the ashes. Then you emptied the receptacle in the basement after the ashes had sufficient time to cool. Before you attempt to sweep ashes into the trap door, be sure there is a proper receptacle in place to catch them.


Will a modem work in the basement?

As long as you have a cable in the basement to plug the modem into (phone line or cable line (coaxial) usually) and a power receptacle a modem will work anywhere.


What is the proper height to mount a receptacle in a basement in Canada building code?

The is no height stated in the CEC as to height of receptacles. If the basement walls are studded out, then install the receptacles at the normal 300 mm above the floor.


How is epithelium connected to underlying connective tissue?

A bAsement membrane


How do you extend the electric outlet at the basement?

Parallel connect the new receptacle to a receptacle in the existing circuit. Black (hot) existing to black (new), white existing to white (new), ground existing to ground (new). Make the ground wire coming into the new receptacle box longer so that it can be looped around the ground screw located in the receptacle box first and then connect to the receptacle without having a break in the wire.


Why should I instal a steam shower in my basement?

Installing a steam shower in the basement is not a good idea. The steam shower should be installed in the nbathroom of your home.


When you use your washer which is new it will flood the basement?

Not if it is all connected properly - have it fitted professionally.


Your Marley electric baseboard heater will not shut of Replaced thermostat Newly installed this heater during your basement remodel?

If it has never worked properly, you probably have somehow connected it improperly. Contact a local electrician or qualified handyman to help wire the heater properly.


Which is a type of epithelium in which all cells are connected to the basement membrane but some of them do not reach the surface?

pseudostratified.


Does homeowners insurance cover replacement of faulty gutters that cause water to go into basement?

No, if the gutters were not installed correctly.