Only a Square D designed breaker can be installed in a Square D manufactured panel.
Depending on how many breakers you have in your exisiting panel if you only have a old 6 or 8 circuit panel then I would suggest a new panel, In the newer building world where you have a 20 or 30 circuit panel then I would suggest a sub panel.
You can buy what are called Tandem circuit breakers. These only take up one space but allow you to connect 2 individual circuits to it. For example, say you had 4 - Single pole 20 amp breakers taking up 4 spaces. You could buy 2 - 20 amp Tandem circuit breakers and that would give you 2 additional spaces in your electrical panel. Just add up all your amps that your circuits will be pulling at one time to make sure you won't be overloading your electrical panel. One drawback to these Tandem breakers is that they are rough on your wallet. They are pretty expensive compared to regular breakers. Hope this helps
No, if you have a Square D distribution panel only Square D breakers will fit in it.
The point where wires interconnect with other wires is known as a "junction". In your panel the circuit breakers are connected to the buss, each circuit breaker feeds a different circuit. Different circuits are not connected together.
I just spoke with an inspector here in NJ today and according to him pending on what panel(squareD)in this case, it is 24 space but can be 48+. Stating that the breakers allow you to place two branch circuits on one breaker. Didn't make sense to me, being that while in school at my union it was 1 circuit for each breaker. Unless, some tandem breakers are used. Check the breaker and see what its rated for. Hope this helps.
To my knowledge Zinsco/Sylvania breakers are the only breakers that will fit in a Zinsco panel. My recommendation as a journeyman electrician is to have your panel changed out. Those panels are old and outdated, not to mention replacement breakers are expensive. Most newer panels, and breakers are the cost of about 2 replacements.
Legally, you must use the same brand breaker with the brand panel. They sell Murray breakers at your area electrical contractor shop, but used I am sure. However, square d homeline, siemens ite, GE, cutler hammer BR do fit but will void the UL listing and are dangerous to mix. Upgrade your panelboard. It is old.
GE circuit breakers with catalog numbers ranging from THQL1115 through to THQL1150 can be substituted like for like with Cutler-Hammer circuit breakers coded CL115 through to CL150, ITE Siemens circuit breakers coded Q115 through to Q150 and Square D circuit breakers coded HOM115 through to HOM150. These are single pole breakers. GE circuit breakers with catalog codes from THQL2115 through to THQL2150 can be substituted with Cutler-Hammer circuit breakers CL215 through to CL250, Square D circuit breakers HOM215 through to HOM250 and ITE Siemens circuit breakers Q215 through to Q250 of the same amperage and voltage. These are double pole breakers.
The breaker panel.
The breaker panel.
There are many ways one can install ge circuit breakers. One can install ge circuit breakers by turning off the power supply, removing the panel cover, testing it for power, and installing it by alining the breaker with the unused panel space.
Circuit breakers can be found in any circuit breaker panel. New circuit breakers can be bought at any shop that sells parts for installing or repairing electrical wiring circuits.
2
If your circuit breakers are in the garage, they would be in a electrical panel (a metal box mounted on a (usually) outside wall, with the electric meter on the outside. The circuit breakers can be either just below the meter on the outside on opposite it inside the garage. It would usually be very close to where the electric connection to the house is. The electrical panel and breakers are not necessarily in the garage.
sqaure D
No, only Sq D breakers will fit into a Sq D panel. I believe Square D makes at least two styles of breakers. Home and industrial. I have a GE entrance/distribution box that has Square D (home), Murray, Bryant, Westinghouse, and GE breakers, all working together. I hope this helps.
As long as the breakers are made to fit the box, there shouldn't be a problem. you can only use breakers listed for the panel, there should be a label on the panel door. It will list all of the breakers approved for use in that panel. If you don't see the breaker by manufacturer name listed, then it should not be used. Lots of brands will interchange, but they have to be listed to be approved.