for USA, Canada and other countries running a 60 Hz supply service.

230 volt single phase refers to the two hot wires in standard house wiring but with the absence of the common return line, aka as the neutral wire.

As using only the "hot" side of phase one (120 volt) and only the "hot" side of phase two (120 volt), so that these two lines yield 240 volts in phase with each other, it is called "single phase".

This is sometime called 230 volts, "double phase" due to the two hot wires. Since both wires have the same phase, the term "double phase" is incorrect. As the two hots are balanced around the neutral point, "Split single phase" is the correct term to use.

Typical usage examples for 240 volts split single phase include: water heaters, electric clothes dryers, water pumps for wells, central and some larger window air conditioning units, air handlers, electric heating units, floor sanders, and portable arc welders.

For Europe

230 V is the standard nominal voltage for single-phase electrical services to residences in Europe. It is obtained from a wye-connected, three-phase, four-wire, 400/230-V transformer secondary, by connecting between any line conductor and the neutral conductor.

User Avatar

Wiki User

12y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

13y ago

A two phase 230 volt circuit is actually one phase, center tapped with grounded neutral so that the voltage from each leg to neutral is 115 volts, and the voltage from leg to leg is 230 volts. It is more properly called split phase, and each of the legs are 180 degrees apart, instead of the 120 degrees normally found in true three phase power.

This answer is:
User Avatar

User Avatar

Wiki User

8y ago

Normally 230 V is single phase system. This has two wires - one is called phase and the other one is called as neutral wire. Neutral wire provides return path where as phase wire provides supply path. In some system there is a third wire called earth wire for safety.

This answer is:
User Avatar

User Avatar

Wiki User

11y ago

A two-phase supply is made up from two supplies on four wires, of equal voltage but in phase quadrature (i.e. 90 degrees apart in time). Two-phase is not used any more because three-phase gives more efficient power transmission.

This answer is:
User Avatar

User Avatar

Wiki User

11y ago

Your question, as expressed, doesn't make any sense. In Europe, a 230-V supply is obtained between any one of the three line conductors and the neutral conductor of a three-phase, four-wire, system.

This answer is:
User Avatar

User Avatar

Wiki User

10y ago

230 V is the standard nominal line-to-neutral voltage in European three-phase systems, which means that the corresponding nominal line voltage is 400 V and it is referred to as 400 V 3-phase.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is 230 volt 3 phase?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Will a 208 volt 3 phase generator supply operate a 230 volt 3 phase motor?

Yes, but the motor's horsepower rating will not be reached.


Can you run single phase 230 from one side of 480 volt 3 phase?

No, you will not obtain 230 volts. From a wye connected three phase 480 volt supply, 277 volts can be obtained from one phase leg and the neutral on the wye connection. 480 volts/1.73 (sq. root of 3) = 277 volts.


Can 3 volt converted to 230 volt?

no


What is the voltage for Sweden?

Outlet for standard electronics is 230 Volt , 50HzThe master feed into Swedish houses is 400 Volt three-phase , 50Hz.When 400 Volt three-phase is split in three single phases it becomes threesingle 230 VoltBigger appliances , e.g Washing-machines, dryers, stoves, used to be400 Volt three-phase, but nowadays most washing-machines and dryersare built for 230 Volt single-phase.


What is the minimum volt rating of wire used in a 3 phase 4160 volt phase to phase system?

5000 volt


What is the ampere of 04 kilowatts at 230 volts in 3 phase?

I(per Phase)=4000/(230*3) = 5.8A


How do you obtain a 230 volts single phase supply from a 400 volts three phase four wire supply?

400 volt three phase on a grounded system is 230 volt single phase, with each phase 120 degrees apart. So, if you have a 400 volt, three phase four wire service (grounded service), you can pull one phase off and reference to the neutral for 230 volt service. Note this may not allow 115 volt service, unless there is also a center tap for each phase.


Can a 230 volt single phase watt hour meter be used to monitor 115 volt single phase?

Yes it would work pretty well but it might not meet its accuracy specification.


How do you connect 230 Volt single phase to a 440 circuit panel?

You can't get 230 from a 440 panel. You'll need a step down trandormer


How do you get a 380 volt 3 phase motor to run on a 220 volt 3 phase power source?

Use a transformer.


Can you use 220 Volt 3 Phase as 208 Volt 3 Phase?

Yes by using a 3-phase transformer. The size depends on how much power has to be converted.


Can a 380volt's 3 phase motor can be converted to 230volt's three phase motor?

Only if you want to damage it. "277" Volt 3-phase will usually mean 277 from each phase to neutral, and 480 from phase to phase. By "230 3-phase", you likely mean 120 phase-to-neutral, and 208 phase-to-phase. If you really mean 230, then you are probably NOT talking about a three phase motor.