if it is a capacitor start and run motor, this is because of shorted capacitor
No
The run capacitor is used when the load is functional while the start capacitor is used to produce the initial torque to drive the load.
If you mean run capacitor, as in the run capacitor for an AC motor, it is usually a round or oval cylinder.
There are two ways to read this: you have a burned-out run capacitor on your motor and a good start capacitor in your parts box, and you have a burned-out start capacitor and a good run capacitor. If the run capacitor's bad and you want to put the higher-voltage start cap in its place, the answer is yes. This is called derating, and the only thing it does for you is increases the lifespan of the capacitor because you're not working it as hard as it can take. If the start capacitor's bad, don't do this--they used a 440-volt capacitor in there for a reason.
Connect your start capacitor in series with the start winding.Connect the run capacitor in the common terminal and Line 1 of the power supply.
A start capacitor is wired in series with the motor's start winding via a centrifugal start switch. The switch disconnects the capacitor and start winding once the motor has reached a pre-determined minimum speed. The motor then continues to run on its main field winding. A different design uses a "start-and-run" capacitor which remains in circuit whilst the motor is running.
true
If the air conditioner has both, the run capacitor is likely the largest one. The start capacitor will only be in the circuit for a very short time, so overheating doesn't become an issue. The run capacitor must be sized for continual use.
Easier to start up. Running remains the same unless it is equipped with a run capacitor too. A run capacitor uses a little less current during run and probably runs a little cooler too.
No, they are two different concepts. The start capacitor is used in conjuction with a starting winding on a single-phase induction motor to produce a small component of rotating field inside the motor. This ensures it rotates the desired way. The run capacitor is used to correct the power-factor of the motor, which reduces the current drawn from the supply for the same amount of power.
A run capacitor and a starter capacitor are not the same thing. A run capacitor is energized the entire time the motor is running, and a start capacitor is not. A run capacitor is one that changes the current on the windings of a single phase AC induction motor to create a rotating magnetic field to energize a second-phase winding. A start capacitor increases starting torque, allowing a motor to be turned on rapidly. It stays in the circuit only long enough to bring the motor to 3/4 of full speed. Some motors then continue to run with a run capacitor.