Q: What is the importance of inductance in transmission line?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Self GMD is used for?

Self GMD, or self-generated master data, is used to maintain and update master data records within an organization without relying on external sources. It helps to ensure the accuracy and integrity of the data by allowing internal departments or individuals to make direct updates to the master data.


How the section of a transmission line can be used as lumped circuit element?

Actually in networks we will consider the elements like resistance, inductance, capacitance as lumped elements for simplicity, like this in power systems we will consider the transmission line parameters(resistance, inductance, capacitance) as lumped elements, because we will calculate all the parameters of power systems with respect to receiving end or sending end but not with respect to middle of the line. If a fault occurs on transmission line then we should not consider the lumped elements of that total transmission line, we should consider the lumped elements from sending end to the point where the fault is occurred.


Why capacitor used in transmission line?

Capacitors can be used to decrease the inductance of power lines (series compensation), and for voltage support (capacitors are put in parallel with the system).


For a transmission line the characteristic impedance with inductance 0.294mHm and capacitance 60pFm?

= Zo = sqrt(L/C) = sqrt(0.294e-3/60e-12) ~ 2214 ohms =


Why conductance is ignored in transmission lines?

Conductance is ignored in short circuit studies because the inductance of the line is the dominant value. Conductance may not be ignored in stability studies.


What is line charging in transmission?

Transmission Line Charging To initially charge the transmission line, the generator voltage stably controlled from 30% of the rated voltage to 110% of the rated voltage by using AVR. The change-over switch (43CH) for initial transmission line charging is mounted on the operator's desk in the main control room.This Voltage Changes are required because of the Stray capacitance effect at the charging and boosts the Voltage at the other end and the inductance of the line drops the Voltage soon after charging


Why there is a phase shift of 30degree in Dyn11 3 phase transformer?

The phase shift is caused by inductance in the transformer. Any inductance from magnetic flux that fails to link both windings is called leakage flux, and the resulting inductance is called leakage inductance.


What are the methods to improve the surge impedance loading of transmission lines?

By increasing Vr,Reducing in series inductance,increase capacitance


How do you double the inductance value without double the number of the turns?

In addition to the number if turns, the inductance also depends on the length and diameter of the winding, the pitch (number of turns per inch), and the material of the core if there is one. Search on line and find an empirical formula for the inductance of a finite coil, and then work to tweak the other parameters to alter the inductance as required.


Does frequency effect total inductance?

Inductance is inductance, and is not a function of frequency. Frequency affects reactance, and ultimately impedance, not inductance.


How do you measure inductance of a coil?

Type your answer here... By use an inductance meter or an inductance bridge


What is inductance comparsion bridge and its application?

It is used to measure the inductance of a coil of unknown inductance.