Best Answer

For USA, Canada and countries running a 60 Hz supply service.

The short answer is yes, the center terminal is the ground wire, and the order of the two hot wires (red and black) does not matter, so long as you don't attach them to the same lug.

If you have a four wire plug in the wall, and are converting a 3 wire appliance, YOU NEED TO USE A FOUR WIRE CORD AND NEVER, EVER CONNECT THE GREEN AND WHITE TOGETHER ON THE CENTER LUG.

If your appliance is old enough, it will have only 3 connection terminals and no place for the ground wire to go. I repeat, DO NOT EVER just put the green ground wire on the center screw terminal, ESPECIALLY if you have a four wire outlet in the wall of your new home. If you do that you will just only be cheating yourself , your wife and anyone else in your house out of a great new safety feature.

What you need to do for an old appliance that has no place for a ground wire is this: you NEED to drill a small hole through the metal case on the dryer that will take a small nut and bolt, and you also need to sand off all of the paint around this nut and bolt so that it will get good contact with the metal case.

So, after you are done, stick the bolt through the hole, install a locknut and tighten it down as much as you possibly can.

Then, you can put the ground wire on the bolt, and install another locknut on top of the ground wire, and also tighten it down as much as you can.

This is the only proper way to upgrade an old appliance to 4 wire.

Also, on an old appliance, there should be a strap connecting the center terminal where the white neutral goes on your older appliance: this strap connects the neutral to the case of the appliance. YOU MUST remove it or cut it by any means necessary or you will just be stuck with a 4 wire upgraded appliance that still acts like a 3 wire. Never just connect the two green and white together if you have 4 wire.

<<>>

for USA, Canada and countries running a 60 Hz supply service

Short answer: yes and no. Some homes built during a certain period can.

Before a new code is adopted there is a lot of anticipation about newer code requirements, and new code requirements usually send manufacturers of products scrambling a year or two before to come up with products that meet the new requirements. But the government almost always allows them to sell off their old stock for a period.

If your home was built very late in 1994, to 1996, when the latest code was adopted, you may already have a 4 wire cable installed with a 3 prong outlet: the installers would just connect the ground to the outlet box or not at all and be done with it. So, in some limited cases, you just might be able to upgrade an outlet from 3 to 4 prong, and still be safe about it.

Otherwise, if the cable only has 3 wires in it, NO, NO, NO.

One exception to that rule: if you have got one of the one in a zillion homes where the builder cared enough to wire it with EMT (conduit). Then, to change anything at al is simple to do: you just run the fourth wire through it. Simple as that.

The reference to Neutral being ground is entirely INCORRECT. Neutral is NOT GROUND.

Wiring a home with EMT is NEVER done. I have been doing this kind of work for a very long time and have never seen or used EMT in a residential application. IN garages, yes, IN industrial environment- It is required but never in a residential situation.

The simplest answer to the original question is: If you presently have a three wire outlet, there would be no need to change to a 4 prong outlet unless some local requirement makes it necessary. The feed to the new outlet would have to be upgraded to a three conductor plus ground .

Other answers

It can BUT there is a reason why you shouldn't do this unless you are a Licensed Electrician: if the appliance NEEDS a four prong receptacle and you just change the receptacle without wiring it up correctly, it will probably be UNSAFE and will also void a) your home's fire insurance cover and b) the warranty of the appliance.

In my 30+ years of experience, a lot of people want to save money on the most dangerous energy source in their home.

It makes much more sense to call a Licensed Electrician and pay to have it done right.

<><><>

(LIFE SAFETY WARNING! [Disclaimer]

Electricity is dangerous!

You can be injured or killed!

Improper installations can cause fire, injury and death!

Should you be doing this yourself?)

1] No!

2] I take it you have a new stove or dryer

3] The old outlet is three prong

4] The new appliance is 4 prong.

5] You have 2 choices

6] Install a new supply cable to feed the appliance with a 4 prong outlet OR utilize the exception to grounding which is allowed in the NEC for existing circuits which lets you reconnect the chassis ground to the neutral [ground] third conductor and change the cord set to a three prong cord - check to make sure your township has not superceded these allowances - the "authority having jurisdiction" has the last say.

7] Secure appropriate permits.

8] Install the equipment according to standard practice in a workmanlike manner!

9] Secure underwriter's inspection! [For your peace of mind.]

or ... call a licensed electrician.

<><><>

This will vary by state. Turn off the power remove the old device. If there are 4 wires present then the device can be changed. If not your local inspector may be able to offer some alternatives.

<><><>

You may need to run new wire to your outlet. Older 3 wire plugs had two hots and a neutral, no dedicated ground. So there may not be a ground wire, or there may not be a neutral wire in the box. You need all four wires to safely wire that new outlet. The new outlet is safer (which is why they changed), so take the time to install it correctly.

<><><>

As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.

Before you do any work yourself,

on electrical circuits, equipment or appliances,

always use a test meter to ensure the circuit is, in fact, de-energized.

IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS.

<><><>

Back to the original question, which was a new dryer being installed in a house with a three-prong dryer outlet.

Your three-prong cord has two thick wires and a thin one. The thin one, which is in the middle, is neutral not ground. When you remove the cover plate over the electrical connections on the new dryer you'll find a terminal block with three screws, and a green screw for ground a couple inches away. Leave the green screw alone; do not connect anything to it because this cord has no ground. The middle wire goes to the middle screw on the terminal block. The two thick wires go to the other two screws, and it doesn't matter which thick wire goes on which screw so long as you don't hook them to the same screw. (Yes, I've seen it. No, it didn't work.)

Now! If you call an electrician and get this outlet changed to four-wire service (which will either be Not Cheap if the electrician can find a ground in your laundry room or Extremely Expensive if he's got to pull wire), the new cord will have red, black, green and white wires coming out of it. Green is Ground, and goes to that green screw you ignored with your three-wire cord. White is neutral (middle screw) and the red and black wires, which are hot, go to the two outside screws.

User Avatar

Wiki User

8y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

9y ago

Dryer receptacle three to four
You are approaching the problem the wrong way around. The cord to the dryer should stay a four wire as that is now the new electrical code. What should be done is changing the three wire wall receptacle to a four wire installation.
Turn the breaker off that controls the circuit for the dryer. Look in the back of the dryer receptacle box that is in the wall. The three wires coming in should have a bare ground wire in the cable set. It wasn't brought to the receptacle because there was no place for it on the old three wire receptacle. If you find the ground wire back there under a screw terminal, just add another short piece of wire under the screw and then connect the other end of the short wire to the new ground terminal on the new four position receptacle. The wire should be equal in size to the size of the wire that exists around the ground terminal now. If the house is so old that the range cable did not have a ground wire in it, the electrical code allows a separate green ground #10 wire to be taken from the breaker panel box to the existing range receptacle. This wire is to be bonded on each end. At the panel end to the ground bus and at the receptacle end around the ground screw at the back of the box unbroken and then to the new four position receptacle ground lug. The two outside terminals of the new receptacle can be interchangeable. Red wire left or right, black wire left or right.

As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.
Before you do any work yourself,
on electrical circuits, equipment or appliances,
always use a test meter to ensure the circuit is, in fact, de-energized.

IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB
SAFELY AND COMPETENTLY
REFER THIS WORK TO QUALIFIED PROFESSIONALS.

This answer is:
User Avatar

User Avatar

Wiki User

12y ago

Yes, the middle wire is the ground, and the other two are interchangable, being legs of 110V each.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: When connecting a 3 prong cord to a new dryer is the middle wire on the cord the ground and does it make a difference where the other 2 wires go?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

When connecting a 4 prong cord to a new dryer red and black are hot What are the green and white wires?

Green is ground and white is neutral.


Where do you ground the extra wire when plugging a 4 prong wire into a three prong outlet for a dryer at?

It may be a 220 Dryer, and you will need a new outlet installed. There should be no extra wires when connecting the Power cord to the plug


Where is the chassis of a dryer?

The chassis of a dryer is what you see when you look at the dryer. It is a frame work of metal that contains the rotating drum and motor assembly. When you ground a dryer it is this framework that the ground wire, from the cord, is connected to.


Should a 3 wire 250 volt drier be grounded?

Yes, most definitely. Provisions for the ground wire in the dryer receptacle should be used. The feeder cable's ground wire is first grounded to the receptacle's junction box ground screw and then taken to the receptacle's ground terminal. The dryer plug configuration will match up to the dryers four wire plug in cable. When the plug is connected into the dryer receptacle the ground terminals of both devices will match and the ground wire will be continuous from the voltage source at the distribution panel and complete the circuit at the dryer. This low impedance electrical path will conduct any ground fault that could occur at the dryer and trip the feeder breaker of the dryer circuit, there by removing the fault current from the dryer circuit.


Why 4 wires for dryer?

The dryer is a 240v dryer so two of the wires are your hot wires, or the ones with power on them. One is your ground wire. And the forth is your neutral.

Related questions

When connecting a 4 prong cord to a new dryer red and black are hot What are the green and white wires?

Green is ground and white is neutral.


Where do you ground the extra wire when plugging a 4 prong wire into a three prong outlet for a dryer at?

It may be a 220 Dryer, and you will need a new outlet installed. There should be no extra wires when connecting the Power cord to the plug


Where is the chassis of a dryer?

The chassis of a dryer is what you see when you look at the dryer. It is a frame work of metal that contains the rotating drum and motor assembly. When you ground a dryer it is this framework that the ground wire, from the cord, is connected to.


Should a 3 wire 250 volt drier be grounded?

Yes, most definitely. Provisions for the ground wire in the dryer receptacle should be used. The feeder cable's ground wire is first grounded to the receptacle's junction box ground screw and then taken to the receptacle's ground terminal. The dryer plug configuration will match up to the dryers four wire plug in cable. When the plug is connected into the dryer receptacle the ground terminals of both devices will match and the ground wire will be continuous from the voltage source at the distribution panel and complete the circuit at the dryer. This low impedance electrical path will conduct any ground fault that could occur at the dryer and trip the feeder breaker of the dryer circuit, there by removing the fault current from the dryer circuit.


Can you wire a external and an internal ground together on a drier?

The ground wire should go from the dryer directly back to the distribution panel. An external ground wire is not required. The ground wire that is in the cord set that is connected to the frame of the dryer and the ground wire that is in the feeders coming from the distribution panel, that is connected to the ground terminal in the dryer receptacle, is all that is required to satisfy the code requirement.


Why 4 wires for dryer?

The dryer is a 240v dryer so two of the wires are your hot wires, or the ones with power on them. One is your ground wire. And the forth is your neutral.


Ground wire burned and broke in half right where cord attaches to back of dryer Why did the ground wire short out on my electric clothes dryer?

The ground wire is NEVER used to provide a reference to create 110v for the controls of the dryer. That is the job of the neutral wire and why dryers are fed with a three wire cable. With the loss of the neutral the dryer would not start as it needs the 120 volts to bring the heating contactor and the motor contactor into activation.In many cases, the ground wire is used to provide a reference to create 110v for the controls of the dryer. With the loss of the ground, the dryer's control circuitry 'floated' as high as 220/240 volts.Usually, the small electric motor that drives the control knob can not handle these voltages, also the control contacts and any additional coils will burn up as well.There could be extensive damage, and may not be worth repairing the dryer.


Does a 4 wire plug for a dryer can be replaced with a 3 wire plug?

The fourth prong is a ground for the body of the dryer. The dryer will work fine with the 3 main ones. Building code requires the four wire plug now, but you can change it and the dryer will work. If you have a 4 plug outlet and a 3 wire cord, you can just change the cord and not use the second ground or connect to the the frame of the dryer.


What is the age of a Kenmore dryer model 11096591240?

This vintage dryer is from 1985-1986 possible even 1984


What is the difference between a commercial dryer and a home dryer?

One difference might be the clothes load capacity of the dryer. Another could be how strong the components like belts, bearings, etc. are. Anything "commercial" is usually built more heavily than standard home units.


How do you wire a three wire 220v for dryer White to white but where does black and ground go?

If the cable you are trying to connect the dryer up to only has a white, black and ground wire, then the dryer is not going to work. The cable needs to be a three wire, the ground wire is never counted when discussing house wiring. Open up the electrical access panel on the back of the dryer. You will see a terminal block. A red and black and white connect to this terminal strip. The "hot" wires are connected to the outside terminals. The neutral (white) wire will be in the center. Connect the ground wire to the frame of the dryer. It is very important that this ground wire be connected as this is the wire that carries the fault current to trip the breaker should a fault arise.


What is the difference between a 4 prong dryer outlet and a 4 prong stove outlet?

The four blade dryer plug brings a separate ground wire from the machine to the electrical grounding system. The three blade dryer plug depended on the neutral wire of the plug to make this connection.